OTDR100x
OTDR Datasheet
Features
◆Handy, lightweight, smart and tablet-inspired design
◆Rugged design built for outside plant
◆IP65 protection level, outdoor enhanced
◆Dynamic range up to 45 dB for up to 240 km point-to-point (P2P)
Product Annotation
1- Stand support
2- USB ports and Ethernet port
3- OTDR port and other optional ports
4- Screen
5- Panel
Specifications
Type |
Testing Wavelength (MM: ±20nm, SM: ±10nm) |
Dynamic Range (dB) |
Event Dead-zone (m) |
Attenuation Dead-zone (m) |
OTDR1001 |
1310/1550 |
32/30 |
1 |
8/8 |
OTDR1002 |
1310/1550 |
37/35 |
1 |
8/8 |
OTDR1003 |
1310/1550 |
42/40 |
0.8 |
8/8 |
OTDR1004 |
1310/1550 |
45/42 |
0.8 |
8/8 |
OTDR1005 |
1310/1490/1550 |
30/28/28 |
1.5 |
8/8/8 |
OTDR1006 |
1310/1550/1625 |
30/28/28 |
1.5 |
8/8/8 |
OTDR1007 |
1310/1490/1550 |
37/36/36 |
0.8 |
8/8/8 |
OTDR1008 |
1310/1550/1625 |
37/36/36 |
0.8 |
8/8/8 |
Technical Specifications | |
Display | 7-in TFT-LCD with LED backlight (touch screen function is optional) |
Interface | 1×RJ45 port, 3×USB port (USB 2.0, Type A USB×2, Type B USB×1) |
Storage | Internal memory: 4GB (about 40,000 groups of curves) |
Battery | 7.4V(dc)/4.4Ah lithium battery (with air traffic certification)
Operating time: 12 hours, Telcordia GR-196-CORE |
Power Supply | 10V(dc), 100V(ac) to 240V(ac), 50~60Hz |
Pulse Width (ns) | Single mode: 5 to 20,000 |
Distance Range (km) | Single mode: 0.1 to 240 |
Sampling Resolution (cm) | 5 Min. |
Sampling Point | Up to 128,000 |
Linearity (dB/dB) | ≤0.05 |
Distance Resolution (m) | 0.01 |
Reflectance Accuracy (dB) | Single mode: ±2, multi-mode: ±4 |
Real-time Refresh (Hz) | 1 |
Distance Accuracy | ±(1m+measuring distance×3×10-5+sampling resolution) (excluding IOR uncertainty) |
IOR Setting | 1.4000~1.7000, 0.0001 step |
Scale Indication | X axis: 4m~70m/div, Y axis: Minimum 0.09dB/div |
Fiber Event Analysis | -Reflective and non-reflective events: 0.01 to 1.99dB (0.01dB steps)-Reflective: 0.01 to 32dB (0.01dB steps)-Fiber end/break: 3 to 20dB (1dB steps) |
Other Functions | Live Fiber detect: Verifies presence communication light in optical fiberTrace overlay and comparison |
VFL Module (Standard) | |
Output Power (mW) | 10, CLASSIII B |
Wavelength (nm) | 650 |
Launching Mode | CW/2Hz |
Optical Connector | FC/UPC |
Power Meter Module (Optional) | |
Wavelength Range (±20nm) | 800~1700 |
Calibrated Wavelength (nm) | 850/1300/1310/1490/1550/1625/1650 |
Test Range (dBm) | Type A: -65~+5 (standard)
Type B: -40~+23 (optional) |
Resolution (dB) | 0.01 |
Accuracy (dB) | ±0.35±1nW |
Modulation Identification | 270/1k/2kHz, Pinput≥-40dBm |
Connector | FC/UPC |
Light Source Module (Optional) | |
Working Wavelength (±20nm) | 1310/1550/1625 |
Output Power (dBm) | Adjustable -25~0 |
Accuracy (dB) | ±0.5 |
Connector | FC/UPC |
Fiber Microscope Module (Optional) | |
Magnification | 400X |
Resolution (µm) | 1.0 |
View of Field (mm) | 0.40×0.31 |
Storage/working Condition (℃) | -18~35 |
Dimension (mm) | 235×95×30 |
Weight (g) | 150 |
Sensor | 1/3 inch 2 million of pixel |
USB | 1.1/2.0 |
Adapter
|
SC-PC-F (For SC/PC adapter)
FC-PC-F (For FC/PC adapter) LC-PC-F (For LC/PC adapter) 2.5PC-M (For 2.5mm connector, SC/PC, FC/PC, ST/PC) |